Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 12(1): e0168902, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28056102

RESUMO

Magnetic Particle Imaging (MPI) is able to provide high temporal and good spatial resolution, high signal-to-noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs). Because of that, MPI is proposed to be a promising future method for cardiovascular imaging. Here, an interesting application may be the quantification of vascular pathologies like stenosis by utilizing the proportionality of the SPIO concentration and the MPI signal strength. In this study, the feasibility of MPI based stenosis quantification is evaluated based on this application scenario. Nine different stenosis phantoms with a normal diameter of 10 mm each and different stenoses of 1-9 mm and ten reference phantoms with a straight diameter of 1-10 mm were filled with a 1% Resovist dilution and measured in a preclinical MPI-demonstrator. The MPI signal intensities of the reference phantoms were compared to each other and the change of signal intensity within each stenosis phantom was used to calculate the degree of stenosis. These values were then compared to the known diameters of each phantom. As a second measurement, the 5 mm stenosis phantom was used for a serial dilution measurement down to a Resovist dilution of 1:3200 (0.031%), which is lower than a first pass blood concentration of a Resovist bolus in the peripheral arteries of an average adult human of at least about 1:1000. The correlation of the stenosis values based on MPI signal intensity measurements and based on the known diameters showed a very good agreement, proving the high precision of quantitative MPI in this regard.


Assuntos
Diagnóstico por Imagem/métodos , Nanopartículas de Magnetita/química , Constrição Patológica , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
2.
Phys Med Biol ; 61(16): N415-26, 2016 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-27476675

RESUMO

Magnetic particle imaging (MPI) uses magnetic fields to visualize the spatial distribution of superparamagnetic iron oxide nanoparticles (SPIOs). Guidance of cardiovascular interventions is seen as one possible application of MPI. To safely guide interventions, the vessel lumen as well as all required interventional devices have to be visualized and be discernible from each other. Until now, different tracer concentrations were used for discerning devices from blood in MPI, because only one type of SPIO could be imaged at a time. Recently, it was shown for 3D MPI that it is possible to separate different signal sources in one volume of interest, i.e. to visualize and discern different SPIOs or different binding states of the same SPIO. The approach was termed multi-color MPI. In this work, the use of multi-color MPI for differentiation of a SPIO coated guide wire (Terumo Radifocus 0.035″) from the lumen of a vessel phantom filled with diluted Resovist is demonstrated. This is achieved by recording dedicated system functions of the coating material containing solid Resovist and of liquid Resovist, which allows separation of their respective signal in the image reconstruction process. Assigning a color to the different signal sources results in a differentiation of guide wire and vessel phantom lumen into colored images.


Assuntos
Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Nanopartículas de Magnetita/química , Modelos Cardiovasculares , Imagens de Fantasmas , Cor , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Nanopartículas de Magnetita/administração & dosagem
3.
IEEE Trans Med Imaging ; 35(10): 2312-2318, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27164580

RESUMO

Magnetic particle imaging (MPI) is able to provide high temporal and good spatial resolution, high signal to noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs), over a wide range practically relevant concentrations. Thus, MPI is proposed as a promising future method for guidance of vascular interventions. To implement this, devices such as guide wires and catheters have to be discernible in MPI, which can be achieved by coating already commercially available devices with SPIOs. In this proof of principle study the feasibility of that approach is demonstrated. First, a Ferucarbotran-based SPIO-varnish was developed by embedding Ferucarbotran into an organic based solvent. Subsequently, the biocompatible varnish was applied to a commercially available guidewire and diagnostic catheter for vascular interventional purposes. In an interventional setting using a vessel phantom, the coating proved to be mechanically and chemically stable and thin enough to ensure normal handling as with uncoated devices. The devices were visualized in 3D on a preclinical MPI demonstrator using a system function based image reconstruction process. The system function was acquired with a probe of the dried varnish prior to the measurements. The devices were visualized with a very high temporal resolution and a simple catheter/guide wire maneuver was demonstrated.


Assuntos
Catéteres , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Nanopartículas de Magnetita , Desenho de Equipamento , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...